| Inspection |
| 1. |
Connect the battery voltage and check the blower motor rotation.
|
| 2. |
If the blower motor does not operate well, substitute with a known-good blower motor and check for proper operation. |
| 3. |
If the problem is corrected, replace the blower motor. |
| Replacement |
| 1. |
Disconnect the negative (-) battery terminal. |
| 2. |
Remove the crash pad and heater & blower unit assembly. (Refer to HA group – “Heater Unit”) |
| 3. |
Disconnect the blower motor connector (A).
|
| 4. |
Remove the blower motor (A) after loosening the screws.
|
| 5. |
Installation is the reverse order of removal. |
Components and components location Component Location Components 1. Intake actuator 2. Air filter 3.
Repair procedures Inspection 1. Measure the resistance between the terminals. 2. The measured resistance is not within specification, the blower resistor must be replaced.
Components and components location Components Repair procedures Removal 1. Disconnect the negative (-) battery terminal. 2. Remove the crash pad lower panel. (Refer to Body - "Crash Pad Lower Panel") 3.
Troubleshooting Troubleshooting Error Item Failure symptom Inspection items Detailed inspections Relevant Parts/ Components Screen display LCD screen does not turn on 1) Connector attachments