WARNING - Windshield heating
Do not use the (
) or (
)
position during cooling operation in extremely humid weather. The difference between
the temperature of the outside air and the windshield could cause the outer surface
of the windshield to fog up, causing loss of visibility.
When the amount of refrigerant is low, the performance of the air conditioning is reduced. Overfilling also has a negative influence on the air conditioning system.
To defog inside windshield 1. Select any fan speed except "0" position. 2. Select desired temperature. 3. Select the or position. 4. The outside (fresh) air will be selected automatically.
Specifications Specification Item Specification Ultrasonic sensor Voltage rating DC 12V Detecting range 11.8 - 47.2 in (30 - 120 cm) Operation voltage DC 9 - 16 V Operation current
Repair procedures Inspection 1. Check the condenser fins for clogging and damage. If clogged, clean them with water, and blow them with compressed air. If bent, gently bend them using a screwdriver or pliers. 2.