Symptoms
|
Possible Causes
|
Remedy
|
Coolant leakage
|
| • |
From the bleed hole of the water pump
|
|
Visually check
|
| • |
Check leaks after about ten-minute warming up.
|
|
| • |
If coolant still leaks, replace a water pump.
|
|
| • |
If leakage stops, reuse the water pump (Do not replace the pump
with a new one).
|
|
|
|
| • |
Check the tightening of the water pump mounting bolts.
|
|
| • |
Retighten the mounting bolts.
|
|
| • |
Check damage of gaskets or inflow of dust.
|
|
| • |
Replace the gasket and clean dust off.
|
|
| • |
From outer surface of water pump
|
|
| • |
Check the material or any cracks of the water pump.
|
|
| • |
Poor material. If any crack found, replace the water pump.
|
|
Noise
|
|
Inspection with a stethoscope
|
| • |
After starting the engine, check noise with a stethoscope.
|
|
| • |
If there is no noise, reuse the water pump (do not replace it).
|
|
| • |
If there is any noise from the water pump, remove the drive belt
and recheck.
|
|
Inspection after removing a drive belt
|
| • |
After removing a water pump and a drive belt, check noise again.
|
|
| • |
If there is noise, reuse the water pump. Check other drive line
parts.
|
|
| • |
If there is no noise, replace the water pump with a new one.
|
|
Inspection after removing a water pump
|
| • |
After removing a water pump and a drive belt, check noise again.
|
|
| • |
If there is any interference between them, replace the water
pump with a new one.
|
|
Overheating
|
|
Loosened impeller
|
| • |
Corrosion of the impeller wing
|
|
| • |
Poor coolant quality / Maintenance check
|
|
| • |
Impeller seperation from the shaft
|
|
| • |
Replace the water pump.
|
|
Other information:
Specifications
Specification
Item
Type
Bulb Watt (W)
Front
Headlamp
Halogen
Low/High
H4 LL
55/60
Turn signal lamp
PY21W
21
Position lamp
W5W
Description and operation
Description
The mode control actuator is located at the heater unit.
It adjusts position of mode door by operating mode control actuator based on
signal of A/C control unit. Pressing mode select switch makes the mode control actuator
shift in order of Vent → Bi-Level → Floor → Mix.