| Inspection |
Vapor hose
| 1. |
Check all the clamps for tightness and the connections for leakage. |
| 2. |
Visually check the vapor lines and hoses for cracks, leaks, loose connections, or deformation. |
Fuel filler cap
| 1. |
Visually check that the fuel tank cap assembly and gasket (A) are not deformed or damaged.
|
Repair procedures Inspection [Kappa 1.0 T-GDI] Check the valve clearance. If necessary, adjust the valve clearance by replacing the tappets.
Description and operation Description The cluster ionizer helps to clean up odors in the vehicle or from the air-conditioner system. When the ignition switch ON, the inoizer runs a "CLEAN" mode and then a "ION" mode, switching every about 15 minutes.
Repair procedures Inspection 1. Turn the ignition switch ON. 2. Manually operate the control switch and measure the voltage of blower motor. 3. Select the control switch to raise voltage until high speed.