| Specification |
Purge Control Solenoid Valve (PCSV)
|
Item |
Specification |
|
Coil Resistance (Ω) |
18.5 - 22.5 [23°C (73.4°F)] |
|
Pin |
2 |
| Description |
Purge Control Solenoid Valve (PCSV) is a solenoid valve and is installed on the surge tank and controls the passage between the canister and the intake manifold.
The evaporative gases gathered in the canister are delivered to the intake manifold when the PCSV is open by ECM control signal.

| Circuit Diagram |

| Inspection |
| 1. |
Turn ignition switch OFF. |
| 2. |
Disconnect PCSV connector. |
| 3. |
Measure resistance between PCSV terminals 1 and 2.
|
| 4. |
Check that the resistance is within the specification.
|
| Removal |
| 1. |
Turn the ignition switch OFF and disconnect the battery negative (-) terminal. |
| 2. |
Disconnect the purge control solenoid valve connector (A) and vapor hoses (B). |
| 3. |
Remove the purge control solenoid valve (C).
|
| Installation |
|
| 1. |
Installation is reverse of removal. |
Specifications Specification Injector Item Specification Coil Resistance (Ω) Approximately 9.
Specifications Specification CVVT Oil Control Valve (OCV) [Bank 1 / Exhaust] Item Specification Coil Resistance (Ω) 6.
Description and operation Description BI-FUNCTION 1. Definition – A headlamp with integrated functions of high and low beam – The light is controlled by rotating the shield inserted to the lens.
Description and operation Description The mode control actuator is located at the heater unit. It adjusts position of mode door by operating mode control actuator based on signal of A/C control unit. Pressing mode select switch makes the mode control actuator shift in order of Vent → Bi-Level → Floor → Mix.