| Component Location |

| Components |

| 1. Intake actuator 2. Air filter 3. Air filter cover 4. Resistor 5. Mosfet 6. Intake seal 7. Intake upper cover |
8. Intake door 9. NVH pad 10. Intake lower cover 11. Blower upper cover 12. Blower lower cover 13. Blower fan 14. Blower motor |
| Replacement |
| 1. |
Remove the heater & blow. (Refer to Heater - "Heater Unit") |
| 2. |
Separate the blower unit from the heater unit after loosening the screws.
|
| 3. |
Installation is the reverse order of removal. |
Repair procedures Inspection 1. Connect the battery voltage and check the blower motor rotation. 2.
Description and operation Description The ambient temperature sensor is located at the front of the condenser and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperature.
Description and operation Description The heater unit includes mode control actuator and temperature control actuator. The temperature control actuator is located at the heater unit. It regulates the temperature by the procedure as follows.